Back to

In-row/In-Rack Cooling

Huawei

FusionModule2000 (Simplified Single-row)

Huawei FusionModule2000 is a new generation smart modular data center solution, which dedicated to providing customers with simple, efficient, and reliable data center solutions.

It’s a modular-designed highly integrated solution which comprises power supply, cooling, rack & structure, cabling, and management system within a module, meeting the requirements for quick delivery and on-demand deployment.

Furthermore the Huawei smart module uses the i3 intelligent management to comprehensively improve the reliability and efficiency of power supply and cooling system. This significantly improves data center availability and O&M efficiency.

Application Scenarios

The FusionModule2000 uses an air-cooled cooling system and is mainly applicable to small and medium sized data centers. The solution features simple design and high building adaptability, lowering the requirements of room height and reconstruction. It meets the data center deployment requirements of various sectors such as enterprise headquarters and large branches, bank headquarters and secondary branches, governments, carriers, education, and healthcare.

Cold & Hot Aisle Containment

High-density

  • In-row cooling, cold and hot aisle containment, can support up to 30 kW/R

Smart

  • Vertical intelligent partitioning precisely matches the heat dissipation of the IT equipment.
  • Intelligent follow-up of air volume and cooling capacity, stable running without hot spots.

Space Saving

  • Supports flexible configuration of integrated UPS, and smart bus, saving 1 to 2 cabinets space.

Reliable

  • Automatic door opening in extreme conditions, ensuring emergency heat dissipation.

NetCol5000-A

NetCol5000-A is an in-row air cooled smart cooling product, adopts DC inverter and high return air temperature design, matches load requirements intelligently. NetCol5000-A uses unique algorithm construct a precision management and intelligent O&M system, makes an efficient, reliable, and simple data center.

Application Scenarios

  • Modular data center
  • Small and medium scale data center

Features

Efficient

  • Variable frequency design: 10%-100% stepless cooling capacity regulation, higher efficiency.
  • Wet film humidifier: saves energy by 95%+ compared with electrode humidifier
  • iCooling algorithm: intelligently optimizes operation status, reduces power consumption by 8%+

Reliable

  • Online maintenance
  • EEV shut automatically
  • Refrigerant detection