PDU – Power Distribution Unit

Basic and Smart PDU

Clever

CLEVER Basic Rack Power Distribution Units provides reliable power distribution to all connected devices in your server rack or networking cabinet. Our Basic PDU are available with a wide range of power input and output options from AC to DC, 1-phase to 3-phase, 10A to 63A. All PDUs are modularized structured and customized production to address your unique requirements. The basic PDUs are provided in various horizontal and vertical configurations to meet your accessibility needs as well.
Based on the innovative SUM (Sustainable, Upgradeable and Maintainable) design concept and Hot-swap technology, user can upgrade the Basic PDU to a Local Metered PDU or a Remote Monitored PDU without power interruption.

Modularized Structure and Customized Production

CLEVER Basic PDU includes a variety of input and output connections to distribute 110V, or 220V power to multiple outlets including IEC320 C13/C19 and Industrial connectors. Having a variety of inputs and outputs allows users to adapt to varying power requirements.

Hot-swap Components

Basic PDU have a wide range of Hot-Swap components Including LED power indicator, Fuse protection, Surge protection, Ammeter etc. Users can upgrade the Basic PDU to a Local Metered PDU or Remote Monitored PDU or replace a failure component without downtime.

Self-designed Locking Receptacles

Each C13 receptacle comes with a self-designed locking system which is suitable for any standard C14 plugs to prevent accidental unplugging and loosening.

Reliable Power Distribution

Basic PDU is designed according to and compliant with CCC/CE/UL/FCC/VED standards. It is not only with powerful function, but also with stable performance, solid quality and high-cost performance.

Managed PDU

Clever Managed PDU has 3 categories: MPDU, ZPDU, RPDU.
Each category has 4 function levels: A, B, C and D.
A : Monitored
В : Per port monitored
C : Switched
D : Per port monitored & switched.

MPDU

The MPDU series is designed to suit the operational requirements of next-generation data centers. MPDU is a Sustainable, Upgradeable and Maintainable (SUM) PDU system which can be re-configured or upgraded hot without affecting the operation of a data center.

Hot-swap NMC module

MPDU has a hot-swap network component to upgrade the function from metered to switched or do the maintenance without affecting the outlet state.

Hot-swap Socket Module

MPDU has hot-swap socket modules with different socket combinations which are very flexible to meet different customer requests.

Large LCD Screen

2.8 ’LCD screen displays the current (Amps), Voltage (Volts), Power (kW), energy consumption (kWh) and power factor. The meter is accurate to +/- 1% and can be rotated 180 degrees allowing the MPDU to be mounted in any orientation.

Flush Mount Hydraulic Circuit Breaker

Low-profile UL 489 certified hydraulic circuit breakers to prevent current overload in each branch circuit and keep PDU running stable. It reduces depth in scenarios where space is limited at the back of the rack for installation.

High-density Outlet Configurations

MPDU is available with up to 42 IEC outlets in a 42U height chassis, allowing more equipment added in high density environments.

Environmental Monitoring

Temperature / Humidity (2 in 1) external sensor can be connected to the MPDU for rack environment monitoring. By connecting a sensor box, MPDU can monitor rack-level temperature, humidity, door position, smoke, and water leakage detection.

Self-designed Locking Receptacles

Each C13 receptacle comes with a self-designed locking system which is suitable for any standard C14 plugs to prevent accidental unplugging and loosening.